Corrosion Rate Sensors
CR-200 Wireless LPR Corrosion Rate Sensor
Inline Sensors
Overview
LPR sensors, such as the CR-300, provide affordable and instant corrosion measurement. The LPR level reading represents the real-time electrochemical measurement of corrosion. Measurements gathered from the CR-300 are instant and represent the “real-time conditioning” on an MPY scale based on the metallurgy being assessed.
The CR-300 corrosion rate sensor is ideal for cooling and process water monitoring. In addition to being reliable and affordable the sensor utilizes the linear polarization resistance (LPR) method to produce a raw signal. The raw signal is conditioned, amplified and digitized inside the sensor. Moreover, this avoids interference from the raw signal caused by long distance wiring. Our corrosion sensors measure sample water conductivity directly. Next it also measures for electrochemical noise. The measured noise data is used to calculate an index to quantify the localized corrosion rate also referred to as pitting.
The CR-300 is ideal for data center applications, enhanced coolant, and water quality monitoring. Able to handle critical systems like condenser and technology cooling. Designed for seamless integration, the 24V DC-powered sensors feature low power demand (<1.5W), with built-in transmitters. Easy or direct communication with DCS or PLC systems and durable 304 stainless steel construction. Enabling operation under high pressures up to 290 psi. These features streamline installation, maintenance, and ensure reliable performance in demanding data center environments.
Specifications
| Item | CR-300 |
| Part Number | 51007 |
| Power Supply | 24VDC, 2W |
| Output | 4-20mA & RS-485 |
| Data Storage | N/A |
| Dimensions | 11.1in L x 0.9in D Lower x 1.7in D Upper |
| Weight | 687g |
| Cable Length | 5ft (1.5m) |
| General Corrosion Range | 0.001-10.000 (MPY Default Based on Metallurgy Selected in uPyxis®) |
| MAX General Corrosion Range | 0.001-995 (MPY Customizable via uPyxis®) |
| Localized Corrosion Range | 0.001-100 (Index Customizable via uPyxis®) |
| MAX Localized Corrosion Range | 0.001-100 (Index Customizable via uPyxis®) |
| Conductivity Compensation | 10-10,000µS/cm |
| Sample Temperature | -20-50 °C |
| Reading Interval | 3-1440 Minutes |
| Resolution | 0.001MPY |
| Alloy Factor | 0-3 (Adjustable Default Assigned via uPyxis® on Metallurgy UNS Code) |
| Installation | Flow Cell with 1inch NPT |
| Enclosure Material | 304 Stainless Steel |
| Working Pressure | up to 100psi (7Bar) |
| Temperature | Working: -10-50 °C Storage: -20-70 °C |
| Protection | IP65 |
| Regulation | CE + RoHS |
Support