Sensor Type: ST-600 Chlorine Sensor (0–16%)
$3,218.00
50231Inline Chlorine Sensor | 0.0–16.0% Mass/Mass | Industrial Bleach
Configurations
Sensor Type: ST-600 Chlorine Sensor (0–16%)
Inline Chlorine Sensor | 0.0–16.0% Mass/Mass | Industrial Bleach
Sensor Type: ST-601 Chlorine Dioxide Sensor (0.0–0.35%)
Inline Chlorine Dioxide Sensor | 0.0–0.35% Mass/Mass | Generator Solution
Sensor Type: ST-604 Chlorine Sensor (0.0–2.00%)
Inline Chlorine | 0.0–2.00% Mass/Mass | Electrolysis
Sensor Type: ST-605 Low Range Chlorine Dioxide Sensor (0–100ppm)
Inline Chlorine Dioxide Low Range Sensor | 0.0–100ppm | Clean Water
Sensor Type: ST-606 Acidified NaClO2 (0–1,200ppm)
Inline Acidified NaClO2 | 0.0–1,200ppm | Clean Water
Sensor Type: ST-607 Chlorine Sensor (0–400ppm)
Inline Chlorine Sensor | 0–400ppm | Clean Water
Overview
The ST-600 Series inline sensors are designed for use in qualitative measurement of real-time mass/mass concentration of a variety of disinfectants to include Chlorine content of concentrated and diluted Sodium Hypochlorite (ST-600 and ST-604), concentration of in-situ Chlorine Dioxide (ClO2) generation solution, low level concentration of Chlorine Dioxide (ClO2) in clean water (ST-605) as well as concentration of Acidified Sodium Chlorite (ASC) in clean water (ST-606), as well as high-range Chlorine concentration in clean water (ST-607) . Unlike typical amperometric sensors for disinfection products the ST-600 Series directly measure the optical density of the solution as either a percentage (% mass/mass) or ppm (mg/L) levels without dilution using a UV light source. The ST-600 Series sensors have a built-in reference light source and a reference light detector in addition to the main light source and main light detector. This configuration ensures a long-term stable measurement of the disinfectant concentration when used in clean (city water quality) carrier water applications. These sensors are factory calibrated using ultra-pure solutions of Sodium Hypochlorite, Chlorine Dioxide and Acidified Sodium Chlorite by Pyxis Lab Inc.
These sensors feature an expanded detection range and an RTD temperature compensated output signal, allowing the user to measure higher temperature compensated concentrations of Sodium Hypochlorite, ClO2 and ASC respectively while obtaining a sample temperature measurement. This feature is highly valuable in compensating for the impact of atmospheric temperature conditions on oxidant solution concentration readings. Pyxis Lab's unique sensor and optical channel design enables these sensors to be installed in both direct contact and non-contact applications. For high volume chemical streams, the ST-001 inline Tee assembly ¾" NPT is utilized. For low flow chemical applications the clear Teflon Tubing ¼" OD may be used to pass through the sensor optical channel for direct concentration measurement.
Break-through Technology measures disinfection liquids from low to high concentrations.
Direct-Read technology without dilution or reagent.
Long maintenance & calibration cycle – 6 Months Trial.
Convenient 3/4" NPT Tee Installation (ST-001) for High Flow Applications.
Convenient 1/4" Teflon Tubing Installation for Low Flow Applications.
Probe Cleanliness Diagnostics via uPyxis 2.0 app.
Expanded Concentration Range
Temperature Compensation (RTD) of Oxidant Concentration & Temperature Output Signal.
Specifications
| Item | ST-600 | ST-601 | ST-604 | ST-605 | ST-606 | ST-607 |
|---|---|---|---|---|---|---|
| Part Number | 50231 | 50231 | 50233 | 54148 | 59433 | 50670 |
| Target Disinfectant | Chlorine | Chlorine Dioxide | Chlorine | ClO₂ Low Range | Acidified NaClO₂ | Chlorine |
| Target Carrier Measured | Industrial Bleach | Generator Solution | Electrolysis | Clean Water | Clean Water | Clean Water |
| Unit of Measure | % Mass/Mass | % Mass/Mass | % Mass/Mass | ppm | ppm | ppm |
| Concentration Output | 0.0–16.0% | 0.0–0.35% | 0.0–2.00% | 0.0–100 ppm | 0.0–1,200 ppm | 0–400 ppm |
| Lower Detection Limit | 0.05% | 0.01% | 0.01% | 0.5 ppm | 2.0 ppm | 1.0 ppm |
| Resolution | 0.001 in Percentage / 0.1 in ppm | |||||
| Accuracy | Two-Point Calibration against User Created Standard Solutions | |||||
| Temp. Output Range | 4mA 0–32°F; 20mA 100–212°F | |||||
| Method | UV Absorbance | |||||
| Power Supply | 22–26VDC, 2W | |||||
| Outputs | Isolated (2) 4–20mA Analog; RS-485 Modbus | |||||
| Dimension | 6.8in L x 1.44in D | |||||
| Weight | 0.37lbs | |||||
| Wet Material | UPVC; Quartz | |||||
| Operating Pressure | Up to 100psi (6.9Bar) | |||||
| Temp. Limitations | 4–49°C (40–120°F) | |||||
| Installation Formats | 1/4" OD Teflon Tubing through Optical Channel; ST-001 3/4" UPVC Tee | |||||
| Cables Included | 5ft/1.5m Bulkhead IP67; 5ft/1.5m Flying Lead IP67 | |||||
| Rating | IP67 | |||||
| Regulation | CE / RoHS / UKCA | |||||
*NOTE* The ST-600 Series sensors include an optical channel composed of titanium compression installed quartz tubing.